Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.142
Filtrar
1.
J Craniomaxillofac Surg ; 52(4): 464-468, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38368205

RESUMO

To clinically and radiographically evaluate patient-specific titanium meshes via a trans-antral approach for correction of enophthalmos and orbital volume in patients with recent unilateral orbital floor fracture. Seven patients with unilateral orbital floor fractures received patient-specific titanium meshes that were designed based on a mirror-image of the contralateral intact orbit. The patient-specific implants (PSIs) were inserted via a trans-antral approach without endoscopic assistance. The patients were evaluated clinically for signs of diplopia and restricted gaze as well as radiographically for enophthalmos and orbital volume correction. Diplopia was totally resolved in two of the three patients who reported diplopia in the upward gaze. Whereas enophthalmos significantly improved in all but two patients, with a mean value of 0.2229 mm postoperatively compared to 0.9914 mm preoperatively. CT scans showed excellent adaptation of the PSIs to the orbital floor with a mean reduction of the orbital volume from 29.59 cc to 27.21 cc, a mean of 0.6% smaller than the intact orbit. It can be concluded that the proposed PSI can offer good reconstruction of the orbital floor through an isolated intraoral transantral approach with minimal complications. It could of special benefit in extensive orbital floor fractures.


Assuntos
Implantes Dentários , Enoftalmia , Fraturas Orbitárias , Humanos , Enoftalmia/diagnóstico por imagem , Enoftalmia/etiologia , Enoftalmia/cirurgia , Diplopia/etiologia , Diplopia/cirurgia , Titânio , Fraturas Orbitárias/complicações , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Órbita/diagnóstico por imagem , Órbita/cirurgia , Estudos Retrospectivos
2.
J Craniomaxillofac Surg ; 52(4): 532-537, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38368208

RESUMO

This study aimed to compare the accuracy of inferomedial orbital fracture restoration using customized orbital implant versus 3D preformed titanium mesh. Patients were divided into two groups. Group 1 underwent surgery with customized orbital implants and intraoperative navigation, while group 2 was treated using 3D preformed titanium meshes with preoperative virtual surgical planning (VSP) and intraoperative navigation. Reconstruction accuracy was assessed by: (1) comparing the postoperative reconstruction mesh position with the preoperative VSP; and (2) measuring the difference between the reconstructed and unaffected orbital volume. Pre- and postoperative diplopia and enophthalmos were also evaluated. Fifty-two patients were enrolled (25 in group 1 vs 27 in group 2). The mean difference between final plate position and ideal digital plan was 0.62 mm (SD = 0.235) in group 1 and 0.69 mm (SD = 0.246) in group 2, with no statistical difference between the groups (p = 0.282). The mean volume differences between the reconstructed and unaffected orbits were 0.95 ml and 1.02 ml in group 1 and group 2, respectively, with no significant difference between the groups (p = 0.860). Overall clinical improvements, as well as complications, were similar. 3D preformed titanium meshes can reconstruct inferomedial fractures with the same accuracy as customized implants. Therefore, in clinical practice, it is recommended to use 3D preformed meshes for this type of fracture due to their excellent results and the potential for reducing time and costs.


Assuntos
Implantes Dentários , Enoftalmia , Fraturas Orbitárias , Implantes Orbitários , Humanos , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Fraturas Orbitárias/complicações , Implantes Orbitários/efeitos adversos , Titânio , Estudos Retrospectivos , Telas Cirúrgicas/efeitos adversos , Órbita/cirurgia , Enoftalmia/etiologia , Enoftalmia/cirurgia
3.
Sci Rep ; 14(1): 3654, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38351033

RESUMO

Postoperative diplopia is the most common complication following orbital fracture repair (OFR). Existing evidence on its risk factors is based on single-institution studies and small sample sizes. Our study is the first multi-center study to develop and validate a risk calculator for the prediction of postoperative diplopia following OFR. We reviewed trauma patients who underwent OFR at two high-volume trauma centers (2015-2019). Excluded were patients < 18 years old and those with postoperative follow-up < 2 weeks. Our primary outcome was incidence/persistence of postoperative diplopia at ≥ 2 weeks. A risk model for the prediction of postoperative diplopia was derived using a development dataset (70% of population) and validated using a validation dataset (remaining 30%). The C-statistic and Hosmer-Lemeshow tests were used to assess the risk model accuracy. A total of n = 254 adults were analyzed. The factors that predicted postoperative diplopia were: age at injury, preoperative enophthalmos, fracture size/displacement, surgical timing, globe/soft tissue repair, and medial wall involvement. Our predictive model had excellent discrimination (C-statistic = 80.4%), calibration (P = 0.2), and validation (C-statistic = 80%). Our model rules out postoperative diplopia with a 100% sensitivity and negative predictive value (NPV) for a probability < 8.9%. Our predictive model rules out postoperative diplopia with an 87.9% sensitivity and a 95.8% NPV for a probability < 13.4%. We designed the first validated risk calculator that can be used as a powerful screening tool to rule out postoperative diplopia following OFR in adults.


Assuntos
Enoftalmia , Fraturas Orbitárias , Adulto , Humanos , Adolescente , Fraturas Orbitárias/cirurgia , Fraturas Orbitárias/complicações , Diplopia/etiologia , Estudos Retrospectivos , Enoftalmia/complicações , Fatores de Risco , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento , Estudos Multicêntricos como Assunto
4.
J Craniomaxillofac Surg ; 52(3): 334-339, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38341367

RESUMO

Isolated orbital floor fractures are more frequent due to low bone thickness (2 mm). The aim of this study was to conduct a retrospective epidemiological analysis on these fractures, investigating demographic variables and fractures' features and their statistical correlation. A total of 120 patients with isolated orbital floor fracture, admitted at the Maxillofacial Surgery Unit of University of Naples Federico II, from 2010 to 2022 were enrolled in the study. Patients were evaluated for age, sex, smoke, comorbidities, post-traumatic clinical manifestation,s and defect side and size. Statistical analysis was conducted using the Pearson regression coefficient (r). The fractures were more frequent in men (male:female 2.2:1) because of road accidents (30% of cases). The average age was 48 years. Enophthalmos, diplopia and ocular motility anomalies were observed in 31%, 23% and 21% of cases, respectively. Statistical analysis revealed that age was related to fracture area; in particular, older patients showed larger fractures (p < 0.001). Interpersonal violence and traffic accidents were related to younger age (p < 0.001). Data analysis revealed that isolated orbital floor fractures are more frequent in young men (<40 years) because of road accidents or interpersonal violence. There is a statistical correlation between fracture area and patient age; in particular, older age corresponds to larger defects.


Assuntos
Enoftalmia , Fraturas Orbitárias , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Órbita/cirurgia , Enoftalmia/etiologia , Fraturas Orbitárias/cirurgia , Demografia
5.
BMJ Case Rep ; 17(2)2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38350703

RESUMO

Craniomaxillofacial trauma is primarily diagnosed and managed by oral and maxillofacial surgeons. Among the cases encountered, midface fractures involving orbital walls are highly prevalent. In these fractures, involvement of the orbital walls, particularly floor of the orbit, can lead to considerable aesthetic and functional limitations. From a maxillofacial perspective, indications for surgical repair of orbital floor encompass marked decrease in ocular motility, fracture affecting more than 50% of surface area, an increase in orbital volume exceeding 18% and enophthalmos greater than 2 mm. In the absence of these discernible signs, surgical intervention is not generally indicated. However, in this case, an early adolescent with a history of midface trauma and minimal orbital floor fracture 8 months earlier presented with progressively delayed onset enophthalmos and hypoglobus closely resembling features of silent sinus syndrome. The enophthalmos and hypoglobus were corrected by placing custom-made non-resorbable high-density polyethylene implant in the orbital floor. Postoperative follow-up demonstrated aesthetically and functionally satisfactory outcomes.


Assuntos
Enoftalmia , Fraturas Orbitárias , Doenças dos Seios Paranasais , Adolescente , Humanos , Enoftalmia/diagnóstico , Enoftalmia/etiologia , Enoftalmia/cirurgia , Órbita/cirurgia , Fraturas Orbitárias/diagnóstico , Fraturas Orbitárias/diagnóstico por imagem , Próteses e Implantes , Movimentos Oculares , Doenças dos Seios Paranasais/cirurgia , Estudos Retrospectivos
6.
J Plast Reconstr Aesthet Surg ; 88: 257-265, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38007998

RESUMO

BACKGROUND: Panfacial bone fractures pose intricate challenges because of severe fragmentation and the loss of landmarks. Surgeons use a variety of reduction techniques, including bottom-up and top-down approaches. This single proportional meta-analysis explores sequencing differences and complications between oral and maxillofacial surgery surgeons (OMSs) and plastic and reconstructive surgeons (PRSs) in treating panfacial bone fractures. METHODS: The PubMed and Scopus databases were searched systematically, and we compiled 14 studies published between 2007 and 2023 involving 1238 patients. A systematic review of the included studies was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines, and data on the reduction techniques; total complication rates; and rates of malocclusion, enophthalmos, infection, asymmetry, and esthetic complications were collected. RESULTS: The bottom-up technique was the most prevalent for both types of surgeons (57.1%, 8 out of 14). Malocclusion rates (I2 = 0% for OMSs and 41% for PRSs) were similar between the groups (p = 0.72), but PRSs tended to have a lower enophthalmos rate (I2 = 0% for OMSs and 32% for PRSs) than OMSs (p < 0.01). Infection rates remained consistent across all studies. However, high heterogeneity was observed for the total complication rate (I2 = 94% for OMSs and 85% for PRSs) and asymmetry and esthetic complications (I2 = 88% for OMSs and 92% for PRSs), making direct comparison between the two groups inconclusive. CONCLUSIONS: In this study, the differences in surgical techniques and levels of interest have a greater impact on the outcomes of the panfacial bone fracture than the surgeon's specialty. However, more in-depth studies are needed to accurately pinpoint panfacial bone fracture reduction trends and differences in postoperative complications in the two expert groups.


Assuntos
Enoftalmia , Fraturas Ósseas , Má Oclusão , Cirurgiões , Humanos , Ossos Faciais/cirurgia , Fraturas Ósseas/cirurgia , Má Oclusão/epidemiologia , Má Oclusão/etiologia
7.
Ophthalmic Plast Reconstr Surg ; 40(1): 49-54, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37581879

RESUMO

PURPOSE: To describe the efficacy and persistence of injectable calcium hydroxyapatite (CAHY) to correct orbital volume deficit in postenucleation socket syndrome. METHODS: An observational study was conducted as a clinical review of all patients in the authors' practice who received injectable CAHY placed in the extraconal and intraconal space to increase orbital volume with a 10-year follow up. The amount of CAHY to be injected was defined according to the degree of orbital volume deficit. Patients previously treated with radiotherapy or with a conjunctival fornix insufficient to accommodate the external prosthesis were excluded. All the patients with at least 10 years of follow up were included in the study. RESULTS: Thirty-one postenucleation socket syndrome patients received injectable CAHY for orbital volume augmentation, with a 10-year follow up. The mean amount of preoperative relative enophthalmos measured by Hertel's exophthalmometry was 14.16 ± 2.15. An increase in the mean orbital volume of 3.35 ± 0.91 at 6 months and 2.97 ± 1.35 at 10 years was obtained. The mean follow-up was 219 ± 18 months (range, 184-240). Patients demonstrated clinical and cosmetic improvement that was observed to continue for 10 years. The complications were peribulbar ecchymosis, 2 extrusions of the internal prosthesis, and 2 ptosis. CONCLUSIONS: Injectable CAHY provides safe, simple, repeatable, and cost-effective technique to treat volume deficiency in the enophthalmic orbit in the long term. The volume augmentation obtained with this semipermanent filler demonstrated a lasting effect in the orbit with negligible loss of volume at 10 years.


Assuntos
Durapatita , Enoftalmia , Humanos , Seguimentos , Estudos Retrospectivos , Enoftalmia/diagnóstico , Enoftalmia/etiologia , Enoftalmia/cirurgia , Órbita/cirurgia , Síndrome
8.
J Neurosurg ; 140(3): 677-687, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37657097

RESUMO

OBJECTIVE: The lateral transorbital approach (LTOA) is a relatively new minimal access skull base approach suited for addressing paramedian pathology of the anterior and middle fossa. The authors define target zones for this approach and describe a series of cases with detailed measurements of visual outcomes, including those obtained with exophthalmometry. METHODS: The authors performed a retrospective analysis of a consecutive series of LTOA patients. Seven target zones were identified: 1) the orbit, 2) the lesser sphenoid wing and anterior clinoid, 3) the middle fossa, 4) the lateral wall of the cavernous sinus and Meckel's cave, 5) the infratemporal fossa, 6) the petrous apex, and 7) the anterior fossa. The authors used volumetric analyses of preoperative and postoperative MR and CT imaging data to calculate the volume of bone and tumor removed and to provide detailed ophthalmological, neurological, and cosmetic outcomes. RESULTS: Of the 20 patients in this cohort, pathology was in zone 2 (n = 10), zone 4 (n = 6), zone 3 (n = 2), zone 1 (n = 1), and zone 5 (n = 1). Pathology was meningioma (n = 10), schwannoma (n = 2), metastasis (n = 2), epidermoid (n = 1), dermoid (n = 1), encephalocele (n = 1), adenoma (n = 1), glioblastoma (n = 1), and inflammatory lesion (n = 1). The goal was gross-total resection (GTR) in 9 patients, all of whom achieved GTR. Subtotal resection (STR) was the goal in 8 patients (5 spheno-orbital meningiomas, 1 giant cavernous sinus/Meckel's cave schwannoma, 1 cavernous sinus prolactinoma, and 1 cavernous sinus dermoid), 7 of whom achieved STR and 1 of whom achieved GTR. The goal was biopsy in 2 patient and repair of encephalocele in 1. Visual acuity was stable or improved in 18 patients and worse in 2. Transient early postoperative diplopia, ptosis, eyelid swelling, and peri-orbital numbness were common. All 9 patients with preoperative diplopia improved at their last follow-up. Seven of 8 patients with preoperative exophthalmos improved after surgery (average correction of 64%). There were no cases of clinically significant (> 2 mm) postoperative enophthalmos. The most frequent postoperative complaint was peri-orbital numbness (40%). There was 1 CSF leak. Most patients were satisfied with their ocular (84%-100% of patients provided positive satisfaction-related responses) and cosmetic (75%-100%) outcomes. CONCLUSIONS: The LTOA is a safe minimal access approach to a variety of paramedian anterior skull base pathologies in several locations. Early follow-up revealed excellent resolution of exophthalmos with little risk of clinically significant enophthalmos. Transient diplopia, ptosis, and peri-orbital numbness were common but improved. Careful case selection is critical to ensure good outcome.


Assuntos
Seio Cavernoso , Cisto Dermoide , Enoftalmia , Exoftalmia , Neurilemoma , Humanos , Diplopia , Seio Cavernoso/diagnóstico por imagem , Seio Cavernoso/cirurgia , Encefalocele , Hipestesia , Estudos Retrospectivos , Exoftalmia/etiologia , Exoftalmia/cirurgia
9.
J Craniofac Surg ; 34(8): 2332-2335, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38011262

RESUMO

Preoperative computer-assisted planning and intraoperative navigation are becoming popular for orbital fracture treatment. However, not all institutions currently have access to these computer-aided applications. The authors present a simple and intuitive operative algorithm to guide orbital fracture reconstructions. The operative algorithm was based on linear measurements of orbital defects on high-resolution Computer tomography (CT) scans using specific axial, coronal, and sagittal plane images. The fractures were then divided into 3 types based on site and defect-size area. For each type, the authors suggested a surgical approach and material reconstruction. Between February 2022 and January 2023, 57 patients were treated according to the described CT-based protocol. The quality of reconstruction was classified as ideal, satisfactory, acceptable, and poor based on postoperative CT. Diplopia, enophthalmos, and postoperative complications were assessed. Fifty-seven patients were included. Forty-four (77.2%) patients were included in the type 1 group, 4 (7.01%) in the type 2 group, and 9 (15.79%) in the type 3 group. The reconstruction was considered ideal in 54 (94.7%) cases, satisfactory in 2 (3.5%), and acceptable in 1 (1.8%). No revision surgery was required. In all cases, preoperative diplopia was settled out, and only 1 patient reported postoperative enophthalmos. No complications occurred, with good clinical results and orbital symmetry. The linear CT measurement-based protocol is a simple and reliable workflow to guide the surgeon's choice of reconstruction material and surgical approach for primary orbital reconstruction. It allows good management of orbital trauma and could help standardize treatment decisions with an imaging technique available in all institutions.


Assuntos
Enoftalmia , Fraturas Orbitárias , Humanos , Enoftalmia/cirurgia , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Fraturas Orbitárias/complicações , Diplopia/cirurgia , Diplopia/complicações , Tomografia Computadorizada por Raios X/métodos , Computadores , Órbita/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
11.
J Oral Maxillofac Surg ; 81(11): 1360-1371, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37689084

RESUMO

BACKGROUND: Although orbital fractures are common, prediction of outcomes in orbital surgery can be quite challenging. PURPOSE: We aim to identify predictors of intraoperative difficulty, operating time, and postoperative examination abnormalities in subjects undergoing post-traumatic orbital reconstructions. STUDY DESIGN, SETTING, AND SAMPLE: This is a retrospective cohort study of all consecutive orbital operations performed at a private, Level 1 trauma center in Portland, Oregon, USA over an 82-month period. All subjects that underwent exploration of the internal orbit for traumatic indications during the study period were included in the cohort. PREDICTOR VARIABLES: Four plating styles, surgical approach (transorbital vs transantral), days from injury to first surgery, fracture size (approximated as a rectangle using linear measurements from computed tomography scans), anteroposterior fracture position, and medial wall involvement were examined. OUTCOME VARIABLES: The primary outcome variable was intraoperative difficulty (defined as requiring revision after intraoperative imaging or return to the operating room). Secondary outcome variables included operating time and postoperative examination abnormalities. COVARIATES: Age and sex were included. ANALYSES: χ2 and Regression analyses were performed using a significance level of P < .05. RESULTS: One hundred and sixty four orbital operations were performed (90 isolated injuries and 74 combined orbital/midface injuries) on 155 subjects (73% male, mean age 39.8 years, standard deviation 16.7). In subjects with isolated orbital fractures, medial wall involvement was associated with intraoperative difficulty (P = .01). When using a transantral approach, intraoperative difficulty was more likely in more anterior fractures (P = .02). Plating style was associated with operating time (P = .03), with median times from 81 to 105 minutes (range 21 to 248 minutes). Postoperative examination abnormalities were more likely in the transorbital approach group (P = .01). Neither days to first surgery nor intraoperative difficulty were associated with postoperative examination abnormalities. Postoperative eyelid changes were seen in 13.6% of transorbital approaches and 0% of transantral approaches. Correction of gaze restriction and enophthalmos were more likely than correction of diplopia (P < .01). CONCLUSIONS AND RELEVANCE: Medial wall involvement is associated with intraoperative difficulty in orbital surgery. Anteriorly positioned fractures are better treated transorbitally, while posterior fractures may be amenable to transantral repair, thus avoiding risk of lower eyelid changes.


Assuntos
Enoftalmia , Fraturas Orbitárias , Humanos , Masculino , Adulto , Feminino , Órbita/diagnóstico por imagem , Órbita/cirurgia , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Fraturas Orbitárias/complicações , Estudos Retrospectivos , Enoftalmia/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
12.
J Craniofac Surg ; 34(6): 1727-1731, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37552131

RESUMO

INTRODUCTION: Orbital blowout fractures are commonly reconstructed with implants shaped to repair orbital cavity defects, restore ocular position and projection, and correct diplopia. Orbital implant shaping has traditionally been performed manually by surgeons, with more recent use of computer-assisted design (CAD). Accuracy of implant placement is also key to reconstruction. This study compares the placement accuracy of orbital implants, testing the hypothesis that CAD-shaped implants indexed to patient anatomy will better restore orbit geometry compared with manually shaped implants and manually placed implants. METHODS: The placement accuracy of orbital implants was assessed within a cadaveric blowout fracture model (3 skulls, 6 orbits) via 3-dimensional CT analysis. Defects were repaired with 4 different techniques: manually placed-manually shaped composite (titanium-reinforced porous polyethylene), manually placed CAD composite, indexed placed CAD composite, and indexed placed CAD titanium mesh. RESULTS: Implant placement accuracy differed significantly with the implant preparation method ( P =0.01). Indexing significantly improved the placement accuracy ( P =0.002). Indexed placed titanium mesh CAD implants (1.42±0.33 mm) were positioned significantly closer to the intact surface versus manually placed-manually shaped composite implants (2.12±0.39 mm). DISCUSSION: Computer-assisted design implants indexed to patient geometry yielded average errors below the acceptable threshold (2 mm) for enophthalmos and diplopia. This study highlights the importance of adequately indexing CAD-designed implants to patient geometry to ensure accurate orbital reconstructions.


Assuntos
Implantes Dentários , Enoftalmia , Fraturas Orbitárias , Procedimentos de Cirurgia Plástica , Humanos , Diplopia/cirurgia , Titânio , Órbita/diagnóstico por imagem , Órbita/cirurgia , Enoftalmia/cirurgia , Polietileno , Cadáver , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia
13.
J Craniofac Surg ; 34(8): 2510-2513, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37622567

RESUMO

The aim of this study is to investigate the feasibility of perpendicular plate of ethmoid as material for the reconstruction of medial orbital wall. The main outcome measurement was preoperative and postoperative orbital volume. The authors performed a study including 17 patients who have isolated medial orbital wall fracture (blow-out fracture). All the patients were fixed the defect using autologous perpendicular plate of ethmoid under endonasal approach. The authors compared the preoperative and postoperative orbital volume difference (unaffected orbit, affected orbit) of all the patients, and observed the improvement of diplopia or ocular motility disorders after operation. All 17 medial orbital wall reconstruction surgeries were successful with no severe postoperative ophthalmic complications. Statistically significant differences were found between the preoperative and postoperative orbital tissue volumes for the affected orbit. There was no statistically significant difference found between the tissue volume of the contralateral unaffected orbit and the affected orbit after reconstruction. And postoperative computed tomography showed the implant is in place and there is no medial rectus incarceration. Autologous perpendicular plate of ethmoid proved to be safe and effective in the reconstruction of medial orbital wall under endonasal approach with cost-effectivence, low complication rate, high biocompatibility, and minimally invasion.


Assuntos
Enoftalmia , Fraturas Orbitárias , Humanos , Órbita/diagnóstico por imagem , Órbita/cirurgia , Músculos Oculomotores , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Fraturas Orbitárias/complicações , Diplopia/etiologia , Nariz , Enoftalmia/cirurgia
14.
J Plast Reconstr Aesthet Surg ; 85: 195-201, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37524031

RESUMO

BACKGROUND: To date, there have been no reports regarding the necessity or methods of reconstruction for cases where the orbital periosteum remains even though the orbital floor bone has been resected in primary reconstruction after total maxillectomy. This study investigated the reconstruction methods for infraorbital wall reconstruction in patients with residual orbital periosteum. METHODS: This was a retrospective cohort study at a single center from June 2010 to June 2019. The following two main cohorts were evaluated: non-reconstruction and reconstruction groups (reconstructed with fascia or costal cartilage) according to whether the orbital floor was reconstructed after total maxillectomy with residual orbital periosteum. The main outcomes were the deviation of the globe evaluated using computed tomography images and subjective signs of diplopia obtained from medical records. RESULTS: Enophthalmos occurred in all five cases in the non-reconstruction group, and diplopia appeared in four cases. In five out of six cases in the reconstruction group, deviation of the globe was not observed. Exophthalmos occurred in one case reconstructed with costal cartilage. Diplopia was not observed in the reconstruction group. In the statistical assessment, a significant difference was observed in the globe deviation between the two groups (P = 0.004). CONCLUSIONS: In cases where the orbital periosteum remains, it is necessary to actively reconstruct the infraorbital wall. Moreover, we believe that the reconstruction with fascia is convenient and useful because it is less invasive, the surgical procedure is simple, and the fascia can be collected from the same surgical field when the flap is elevated. LEVEL OF EVIDENCE: 4 (retrospective cohort study).


Assuntos
Enoftalmia , Fraturas Orbitárias , Procedimentos de Cirurgia Plástica , Humanos , Procedimentos de Cirurgia Plástica/efeitos adversos , Periósteo , Estudos Retrospectivos , Retalhos Cirúrgicos/cirurgia , Órbita/diagnóstico por imagem , Órbita/cirurgia , Enoftalmia/cirurgia , Fraturas Orbitárias/cirurgia
15.
J Craniofac Surg ; 34(6): 1672-1676, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37427923

RESUMO

OBJECTIVE: For patients without dysfunctions, the main purpose of secondary correction for craniofacial fractures is restoring facial symmetry. Computer-assisted surgery techniques including virtual surgical planning and intraoperative navigation provide the help to restore the bony symmetry as much as possible. The authors retrospectively quantitatively analyzed patients who received computer-assisted secondary correction for craniofacial fractures on facial symmetry pre and postoperation. METHODS: This observational study reviewed the medical records of 17 patients requiring secondary correction for craniofacial fractures. Pre and postoperative computed tomography data were used to quantitatively analyze the changes in facial symmetry and enophthalmos. RESULT: All patients enrolled in this study showed mid-facial asymmetry but without dysfunctions except for enophthalmos, and 5 patients had bone defects in the frontal-temporal area. The corrective surgical techniques were different for each patient according to their specific condition. Virtual surgical planning with or without intraoperative navigation was performed for all patients. Compared with the preoperative condition, their facial symmetry was significantly improved. The maximum discrepancy value between the affected side and the mirrored unaffected side decreased from 8.10 ± 2.69 to 3.74 ± 2.02 mm postoperatively, and the mean discrepancy value decreased from 3.58 ± 1.29 to 1.57 ± 0.68 mm. In addition, the Enophthalmos Index decreased from 2.65 to 0.35 mm. CONCLUSION: This observational study objectively demonstrated that computer-assisted secondary correction for craniofacial fractures can significantly improve facial symmetry. And the authors recommend that virtual surgical planning and intraoperative navigation should be a must step in craniofacial fracture correction.


Assuntos
Enoftalmia , Fraturas Orbitárias , Cirurgia Assistida por Computador , Fraturas Zigomáticas , Humanos , Enoftalmia/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Fraturas Zigomáticas/diagnóstico por imagem , Fraturas Zigomáticas/cirurgia , Fraturas Zigomáticas/complicações , Cirurgia Assistida por Computador/métodos , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Fraturas Orbitárias/complicações , Assimetria Facial/diagnóstico por imagem , Assimetria Facial/etiologia , Assimetria Facial/cirurgia , Computadores , Imageamento Tridimensional/métodos
16.
Oral Maxillofac Surg Clin North Am ; 35(4): 585-596, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37302946

RESUMO

The unique anatomy and physiology of the growing craniofacial skeleton predispose children to different fracture patterns as compared to adults. Diagnosis and treatment of pediatric orbital fractures can be challenging. A thorough history and physical examination are essential for the diagnosis of pediatric orbital fractures. Physicians should be aware of symptoms and signs suggestive of trapdoor fractures with soft tissue entrapment including symptomatic diplopia with positive forced ductions, restricted ocular motility (regardless of conjunctival abnormalities), nausea/vomiting, bradycardia, vertical orbital dystopia, enophthalmos, and hypoglobus. Equivocal radiologic evidence of soft tissue entrapment should not withhold surgery. A multidisciplinary approach is recommended for the accurate diagnosis and proper management of pediatric orbital fractures.


Assuntos
Enoftalmia , Fraturas Orbitárias , Adulto , Criança , Humanos , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Tomografia Computadorizada por Raios X , Náusea , Vômito , Exame Físico
17.
Otolaryngol Clin North Am ; 56(6): 1101-1112, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37380516

RESUMO

Orbital floor fractures are a common manifestation of facial trauma that is encountered by ophthalmology, otolaryngology, and oral maxillofacial specialists. Surgical intervention is required emergently in cases of tissue entrapment and less urgently in cases of presenting with persistent diplopia, enophthalmos greater than 2 mm, and/or fractures involving greater than 50% of the orbital floor. Surgical management is a debated topic with differing opinions among surgeons regarding timing of repair, type of implant, and surgical approach.


Assuntos
Enoftalmia , Fraturas Orbitárias , Procedimentos de Cirurgia Plástica , Humanos , Fraturas Orbitárias/cirurgia , Enoftalmia/cirurgia , Ossos Faciais/cirurgia , Próteses e Implantes , Estudos Retrospectivos
18.
Artigo em Inglês | MEDLINE | ID: mdl-37316426

RESUMO

OBJECTIVE: This case series aims to highlight the digital workflow used by our institution to treat orbital fractures by creating individualized implants using point-of-care, 3-dimensional (3D) printed models. STUDY DESIGN: The study population comprised consecutive patients who presented to John Peter Smith Hospital with isolated orbital floor and/or medial wall fractures from October 2020 to December 2020. Patients treated within 14 days of their initial injury and with 3 months postoperative follow-up were included. Bilateral orbit fractures were excluded because an intact contralateral orbit is needed for 3D modeling. RESULTS: A total of 7 consecutive patients were included. The orbital floor was involved in 6 of the fractures, whereas 1 fracture involved the medial wall. All patients with preoperative diplopia, enophthalmos, or both had resolution by the 3-month postoperative follow-up appointment. Postoperatively, there were no complications in all patients included. CONCLUSIONS: The point-of-care digital workflow presented allows for the efficient production of individualized orbital implants. This method may produce a midface model in hours that can be used to pre-mold an orbital implant to the mirrored, unaffected orbit.


Assuntos
Enoftalmia , Fraturas Orbitárias , Implantes Orbitários , Humanos , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Sistemas Automatizados de Assistência Junto ao Leito , Órbita , Enoftalmia/complicações , Enoftalmia/cirurgia , Implantes Orbitários/efeitos adversos , Estudos Retrospectivos
19.
Eur Ann Otorhinolaryngol Head Neck Dis ; 140(4): 177-180, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37147225

RESUMO

INTRODUCTION: Silent sinus syndrome (SSS) is a rare entity, almost exclusively involving the maxillary sinus, frontal location being very rarely reported. The aim of the present study was to describe clinical and radiological characteristics and surgical treatment using the CARE methodology. RESULTS: One woman and 2 men were referred for chronic unilateral frontal pain with imagery showing silent sinus syndrome. All showed partial or complete liquid opacification of the affected sinus associated with a thin interfrontal sinus (IFS) retracted toward the affected sinus. Functional endoscopic sinus surgery was performed in all cases, with good functional results. DISCUSSION: We describe 3 cases of SSS with IFS involvement. The frontal sinus wall seemed most vulnerable, probably most liable to be weakened by atelectasis. The study suggests that frontal SSS can be an etiology in chronic frontal sinusitis. Preoperative findings of IFS retraction are useful for surgical restoration of frontal sinus ventilation, relieving chronic pain and preventing complications.


Assuntos
Enoftalmia , Doenças dos Seios Paranasais , Masculino , Feminino , Humanos , Enoftalmia/complicações , Enoftalmia/cirurgia , Tomografia Computadorizada por Raios X , Síndrome , Doenças dos Seios Paranasais/complicações , Doenças dos Seios Paranasais/diagnóstico , Doenças dos Seios Paranasais/cirurgia , Seio Maxilar/cirurgia , Endoscopia
20.
Ophthalmic Plast Reconstr Surg ; 39(5): e155-e158, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37195826

RESUMO

A 26-year-old female presented with left enophthalmos following orbital floor and medial wall fracture despite surgical repair. She underwent further exploration and surgical repair but the enophthalmos persisted at 3-4 mm. Following discussion, she received 2 ml of hyaluronic acid filler injection into the posterior orbit and intraconal space. There were no immediate postoperative complications with normal optic nerve function, and the enophthalmos improved by 2 mm. The optic nerve function remained normal at the 4-week review. She returned 30 months following the injection with left periorbital edema, subjective red desaturation, and reduced peripheral visual field. On examination, there was a left relative afferent pupillary defect, disc pallor, and reduced visual field defect on automated visual field test. Following transcutaneous orbital injection of hyaluronidase, there was a subjective improvement in red desaturation with an improved peripheral visual field. Here the authors present a case of compressive optic neuropathy of delayed onset following orbital hyaluronic acid filler injection.


Assuntos
Enoftalmia , Doenças do Nervo Óptico , Feminino , Humanos , Adulto , Hialuronoglucosaminidase , Ácido Hialurônico/efeitos adversos , Doenças do Nervo Óptico/diagnóstico , Nervo Óptico , Órbita/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...